Marsh Funnel Viscosity Test Procedure
March Funnel
The following Marsh funnel viscosity test procedure is used for measuring funnel viscosity for Water Based Mud, Oil Based Mud or completion fluid:
1. Check that the narrow discharge tube at the base of the funnel is clear.
2. Hold the Marsh Funnel upright, place a finger over the discharge tube and use a mud cup to fill the funnel until level with the wire-mesh screen, using the wire-mesh screen to remove larger particles that might block the narrow discharge tube.
3.